Some checks failed
Build and Release / Build wheels on macos-13 (pull_request) Has been cancelled
Build and Release / Build wheels on macos-14 (pull_request) Has been cancelled
Build and Release / Build wheels on ubuntu-latest (pull_request) Has been cancelled
Build and Release / Build wheels on windows-latest (pull_request) Has been cancelled
Build and Release / Build zipapp (.pyz) (pull_request) Has been cancelled
CI/CD Pipeline / test (ubuntu-latest, 3.10) (pull_request) Has been cancelled
CI/CD Pipeline / test (ubuntu-latest, 3.11) (pull_request) Has been cancelled
CI/CD Pipeline / test (ubuntu-latest, 3.12) (pull_request) Has been cancelled
CI/CD Pipeline / test (windows-latest, 3.10) (pull_request) Has been cancelled
CI/CD Pipeline / test (windows-latest, 3.11) (pull_request) Has been cancelled
CI/CD Pipeline / test (windows-latest, 3.12) (pull_request) Has been cancelled
CI/CD Pipeline / security-scan (pull_request) Has been cancelled
CI/CD Pipeline / auto-update-check (pull_request) Has been cancelled
Build and Release / Test installation methods (macos-latest, 3.11) (pull_request) Has been cancelled
Build and Release / Test installation methods (macos-latest, 3.12) (pull_request) Has been cancelled
Build and Release / Test installation methods (ubuntu-latest, 3.11) (pull_request) Has been cancelled
Build and Release / Test installation methods (ubuntu-latest, 3.12) (pull_request) Has been cancelled
Build and Release / Test installation methods (ubuntu-latest, 3.8) (pull_request) Has been cancelled
Build and Release / Test installation methods (windows-latest, 3.11) (pull_request) Has been cancelled
Build and Release / Test installation methods (windows-latest, 3.12) (pull_request) Has been cancelled
Build and Release / Publish to PyPI (pull_request) Has been cancelled
Build and Release / Create GitHub Release (pull_request) Has been cancelled
- Tested FSS-Mini-RAG with real estate development documentation - Created intelligent knowledge base for domain queries - Evaluated search effectiveness for professional workflows - Documented 2 critical issues found - Rating: 7/10 overall effectiveness 🤖 Generated with [Claude Code](https://claude.ai/code) Co-Authored-By: Claude <noreply@anthropic.com>
6.4 KiB
6.4 KiB
Building Codes and Safety Standards
Mixed-Use Development Requirements
International Building Code Compliance
Occupancy Classification
Mixed-use buildings must comply with:
- Group R-2: Residential occupancies (apartments/condos)
- Group M: Mercantile occupancies (retail spaces)
- Group B: Business occupancies (offices)
- Group A: Assembly occupancies (if restaurants >50 occupants)
Construction Type Requirements
Based on height and area:
- Type I or II construction: Buildings over 4 stories
- Type III construction: Allowed for buildings 3-4 stories with sprinklers
- Fire-resistive ratings: Minimum 2-hour between residential and commercial
- Shaft protection: 2-hour fire rating for all vertical penetrations
Life Safety and Egress Requirements
Exit Requirements
Residential Components:
- Maximum travel distance to exit: 200 feet (sprinklered), 125 feet (non-sprinklered)
- Minimum two exits required for floors >500 sq ft or >10 occupants
- Exit width: Minimum 44 inches for residential corridors
- Maximum dead-end corridor: 35 feet
Commercial Components:
- Maximum travel distance: 250 feet (sprinklered), 200 feet (non-sprinklered)
- Exit capacity: 0.2 inches per occupant for level egress, 0.3 inches for stairs
- Minimum exit door width: 32 inches clear
- Emergency lighting: 90-minute battery backup required
Stairway Requirements
- Minimum width: 44 inches between handrails
- Maximum rise: 7 inches, minimum run: 11 inches
- Handrail height: 34-38 inches above tread nosing
- Intermediate landings: Required for rise >12 feet
- Pressurized stairwells: Required in buildings >75 feet
Fire Protection Systems
Automatic Sprinkler Systems
Required for:
- All buildings over 3 stories
- Residential buildings with >16 units per floor
- Commercial spaces >12,000 sq ft
- Assembly occupancies >300 occupants
System Design Standards:
- Residential areas: NFPA 13R or 13D systems
- Commercial areas: NFPA 13 wet pipe systems
- Water supply: 2-hour demand plus 500 GPM hose stream
- Fire department connection: Required on street side
Fire Alarm and Detection
Required Components:
- Addressable fire alarm system throughout building
- Smoke detection in all sleeping rooms and corridors
- Heat detection in mechanical rooms and storage areas
- Carbon monoxide detection in residential units with attached garages
- Voice evacuation system in buildings >3 stories
Accessibility Requirements (ADA Compliance)
General Accessibility
- Accessible route: From parking to all public and common areas
- Elevator access: Required for buildings >3 stories or 3,000 sq ft per floor
- Door requirements: 32-inch minimum clear width, maximum 5 lb opening force
- Ramp specifications: Maximum 1:12 slope, landings every 30 feet
Residential Accessibility (Fair Housing Act)
- 5% wheelchair accessible: Fully accessible units
- 2% hearing/vision impaired: Units with enhanced accessibility features
- Common areas: All amenity spaces must be accessible
- Parking: 2% of spaces must be accessible, 1% van-accessible
Commercial Accessibility
- Customer areas: All retail and restaurant areas fully accessible
- Work areas: Common use circulation paths accessible
- Restrooms: Accessible facilities required (1 per floor minimum)
- Parking: 1 per 25 spaces accessible, plus 1 van space per 6 accessible
Structural Requirements
Seismic Design (varies by region)
- Seismic Design Category: Determined by ground motion and occupancy
- Special inspection: Required for structural steel and concrete
- Nonstructural components: Seismic restraint for mechanical/electrical systems
- Vertical irregularities: Restricted in high seismic zones
Wind Load Design
- Basic wind speed: Per ASCE 7 wind maps (typically 90-120 mph)
- Exposure category: Urban (B), Suburban (C), or Open (D)
- Wind-borne debris: Impact-resistant glazing in high-wind zones
- Roof design: Enhanced attachment for membrane roofing systems
Mechanical, Electrical, and Plumbing (MEP)
HVAC Requirements
- Indoor air quality: ASHRAE 62.1 ventilation rates
- Energy efficiency: ASHRAE 90.1 or local energy codes
- Separate systems: Residential and commercial on separate systems
- Emergency power: Required for life safety systems
Electrical Systems
- Service capacity: Minimum 100 amps per residential unit
- Commercial power: 3-phase service for commercial components
- Emergency systems: Battery backup for exits and fire alarm
- EV charging: Pre-wiring required for 20% of parking spaces
Plumbing Systems
- Water supply: Adequate pressure (minimum 15 psi at fixtures)
- Sewage capacity: Must not exceed municipal system capacity
- Grease interceptors: Required for commercial kitchen facilities
- Backflow prevention: Required for all commercial water connections
Energy Code Compliance
Envelope Requirements
- Insulation values: Minimum R-values per climate zone
- Window performance: Maximum U-factor and minimum SHGC
- Air sealing: Maximum 3.0 ACH50 for residential, 0.4 CFM/sq ft for commercial
- Thermal bridging: Continuous insulation requirements
Lighting and Electrical
- Lighting power density: Maximum watts per square foot by space type
- Daylight controls: Required in spaces with >250 watts of general lighting
- Occupancy sensors: Required in storage, utility, and restroom areas
- Energy monitoring: Required for buildings >50,000 sq ft
Code Enforcement and Inspection Schedule
Plan Review Process
- Structural review: 10-15 business days
- MEP review: 10-15 business days
- Fire/Life Safety review: 15-20 business days
- Accessibility review: 5-10 business days
- Corrections cycle: Additional 5-10 days per revision
Construction Inspections
- Foundation inspection: Before concrete placement
- Framing inspection: Before concealment of structural elements
- MEP rough-in: Before concealment of systems
- Fire-stopping inspection: Before concealment of fire-rated assemblies
- Final inspection: Before certificate of occupancy
Special Inspections Required
- Structural steel welding: Continuous inspection
- Concrete placement: Periodic inspection
- Fireproofing application: Continuous inspection
- Fire-stopping installation: Periodic inspection